You need 50 mm of motorised travel and a payload the MTS50-Z8 cannot take, or you need it sooner than it ships.

Where we are stronger

Nearly 2× the payload and 8× the velocity, both published like-for-like

Where Thorlabs is

Closed loop, and a documented specification for a qualification file

Every Thorlabs figure below is read from their own published document, cited at the foot of this page. Figures that share a unit but were not measured the same way are kept in a separate table and marked — why that distinction decides the comparison.

Measured the same way

directly comparable
ParameterThorlabs MTS50-Z8CYGX80-0802-50-42UnitBasis
Travel5050mmTotal stroke, both catalogues.
Maximum velocity2.420mm/sManufacturer maximum, both catalogues.
Max horizontal load1220kgOn-axis centred load, both catalogues.
TableNot stated in the manual specification table80×100mmMounting surface.
Stage mass0.341.53kgStage only, no controller.
Lead screw1.0 mm pitchφ8, 2 mm lead—Screw lead per revolution.
GuidewayNot stated in the manual specification tableCrossed roller—Bearing type.

Same unit, different measurement

not comparable as printed
ParameterPublished figuresWhy they do not compare
Repeatability (µm)

Thorlabs ± 0.8 — Bidirectional, stated as such in the manual.

Ours ± 0.3 — The supplied catalogue gives one ± figure and does not say whether it is unidirectional or bidirectional.

These are not the same measurement. A unidirectional figure is always the flattering one, and ours is not labelled. Until the basis is confirmed, read our ± 0.3 µm as not directly comparable to their ± 0.8 µm — not as better than it.
Positioning accuracy (µm)

Thorlabs 290 (absolute on-axis, over 50 mm) — Absolute on-axis accuracy over full travel, closed loop.

Ours 5 — Catalogue figure. No measurement standard, test temperature or load condition is stated.

These are not comparable figures. The gap is far too large to be a product difference and is almost certainly a difference in what was measured: Thorlabs publishes an absolute error accumulated over the whole 50 mm, and the supplied catalogue does not say what its 5 µm covers or over what distance. Do not design to our figure without asking engineering to confirm the basis.

What separates them

drive class

They are not the same class of machine, and that matters more than any single number.

MTS50-Z8 — Closed-loop DC servo: a rotary encoder on the motor feeds position back to the controller, which corrects to the commanded point.

CYGX80-0802-50-42 — Open-loop stepper: the controller counts steps and trusts the mechanics. There is no position feedback, so a missed step is not detected or corrected.

Everything below is read out of the two published catalogues. Where a figure is the manufacturer's, the source is named. Where the two numbers share a unit but were not measured the same way, they are in a separate table and the difference is spelled out, because in this category that is where specification errors come from.

When to stay with Thorlabs

honestly
  • You need position feedback. The MTS50-Z8 is closed loop; an open-loop stepper does not detect a missed step.
  • You are already on Kinesis or APT and the stage has to drop into that system.
  • You need a revision-controlled specification for a qualification file.

When the CYGX80-0802-50-42 is the better buy

what we actually compete on
  • The payload is above 12 kg. This is the one headline figure where the published, like-for-like numbers favour us, and by a wide margin.
  • Cycle rate matters: eight times the maximum velocity, same basis, both catalogues.
  • The schedule cannot absorb a lead time.

Source

where their figures come from

Thorlabs figures on this page are read from MTS25-Z8 and MTS50-Z8 Brushed DC Motorized Translation Stages, HA0210T Rev K, Thorlabs, July 2021. Manufacturer user manual, Chapter 5 Specifications. We do not reprint their drawings or images. Confirm the current revision against Thorlabs before you design to any of it — and confirm ours in the quotation before you order.

The CYGX80-0802-50-42

full specifications and drawing
CYGX80-0802-50-42 linear stage, three-quarter view
Travel50mm
Table80×100mm
Max speed20mm/s
Load20kg

Stock and despatch are confirmed on the quotation for the quantity you need.

Application & quotation

Start an inquiry